Me yasa Tsarin Gwajin Resonant AC ke haifar da wuce gona da iri?
Mafi girman ƙarfin ƙarfin samfurin da aka gwada da kuma ɗigogi na reactance na na'urar gwajin gwaji, mafi ƙaranci tasirin ƙarfin ƙarfin.Don haka, lokacin da muka gudanar da gwajin ƙarfin ƙarfin AC na jerin resonance babban ƙarfin gwajin abu, ana buƙatar kai tsaye a auna v.Kara karantawa -
Hanyar gwaji mai jujjuyawa ta Canjin Canjin Analyzer
Yanayin jujjuyawa mai jujjuya mai jujjuyawa ta famfo mai canzawa: Hanyar wayoyi (wannan yana ƙayyade juriya algorithm, dole ne ya zama daidai);YO nau'in wiring shine cewa taranfomar yana da tsaka tsaki;Ana zana nau'in nau'in nau'in nau'in Y daga mai canzawa ba tare da tsaka tsaki ba;△ irin wayoyi Lokacin gwaji, ...Kara karantawa -
Ka'idar Pulse Hanyar Yanzu na Mai gano Sashe na Dijital
Lokacin da ƙarfin filin wutar lantarki da aka yi amfani da shi a cikin kayan lantarki ya isa ya haifar da fitarwa a cikin yanki na insulating, amma yanayin fitarwa wanda ba a kafa tashar fitarwa ba a cikin wurin fitarwa ana kiransa partial fitarwa....Kara karantawa -
Hanyar nemo maki resonance a cikin gwajin jigila na kebul
Gwajin resonance na jerin kebul yana nufin gwajin jurewar wutar lantarki na kebul ta amfani da na'urar gwajin jigila.Bugu da kari, na'urar kuma za ta iya yin gwaje-gwajen rufe fuska a kan tasfoma, GIS, da na'urorin lantarki ban da babban iko.GDTF jerin kebul na juyawa mitar mitar s...Kara karantawa -
Menene ma'anar gano ɓarna na fitarwa don samfuran rufi?
Gano ɓangaren fitarwa yana da mahimmanci ga manyan igiyoyi masu ƙarfin lantarki da kuma nazarin halayen juzu'i a cikin rufi, musamman igiyoyin wutar lantarki....Kara karantawa -
Menene manyan aikace-aikacen kyamarar hoto na thermal GD-877?
HV HIPOT GD-877 infrared thermal imager yana ɗaukar mai gano 25um160*120, kuma kewayon ma'aunin zafin jiki shine -20°C~+650°C....Kara karantawa -
Manufar da hanyar gwaji na AC jure wa gwajin wutar lantarki na gidan wuta
Gwajin jurewar wutar lantarki na AC gwaji ne wanda a cikinsa ana amfani da wutar lantarki ta sinusoidal power mitar AC wanda ya wuce wasu nau'ikan wutar lantarki da aka ƙididdigewa ga injin da aka gwada tare da bushing, kuma tsawon lokacin shine 1min.Manufar ita ce a yi amfani da wutar lantarki ta gwaji ...Kara karantawa -
Mene ne bambanci tsakanin wutar lantarki da na'ura mai canzawa?
Mene ne bambanci tsakanin wutar lantarki ta wutar lantarki da na'urorin wuta na yanzu dangane da ka'idodin aikin su?HV HIPOT GDP ...Kara karantawa -
Yadda za a warware matsalar overvoltage na mitar AC resonant gwajin tsarin?
Ana amfani da tsarin gwajin resonant na mitar AC don gano ƙarfin rufewa na kayan lantarki.Yana da mahimmancin mahimmanci don yin hukunci ko za'a iya saka kayan lantarki cikin aiki.Hakanan hanya ce mai mahimmanci don tabbatar da matakin rufewa na kayan aiki da kuma guje wa ...Kara karantawa -
Menene amsawar mitar mai juyawa?
Nakasar iska tana nufin canje-canjen da ba za a iya jurewa ba a cikin girma da siffar iskar da ke ƙarƙashin aikin injina da wutar lantarki.Ya haɗa da canje-canje a cikin girman axial da radial, ƙaurawar jiki, jujjuyawar iska, kumbura da guntun wando na tsaka-tsaki, da sauransu. Dalili kuwa shine t...Kara karantawa -
Rigakafin Mai Nazari Chromatography
HV HIPOT GDC-9560B Tsarin wutar lantarki Insulation Oil Gas Chromatography Analyzer Shigarwa da cire ginshiƙi na chromatographic: 1. Shigarwa da cirewa na chromatographic...Kara karantawa -
Aikace-aikacen Nazartar ingancin Wuta
A cikin ainihin gwaji da bincike na ingancin wutar lantarki, ana buƙatar mai nazarin ingancin wutar lantarki.Ana amfani da wannan na'ura sosai wajen auna ingancin wutar lantarki kuma ta shahara sosai a tsakanin ma'aikatan wutar lantarki.A cikin wannan labarin, HV Hipot zai ba da taƙaitaccen gabatarwa don wannan kayan aikin ...Kara karantawa