Jagoran Fasaha
-
Fasalolin da ayyuka game da HV HIPOT CT/PT Analyzer
HV HIPOT GDHG-201A Transformer Comprehensive CT/PT Analyzer (masu canza mitar mai canzawa volt-ampere halayyar ma'auni) kayan aikin gwaji ne na musamman da ake amfani da shi don kariyar gudu da wutar lantarki mai ƙarfi don gwada masu taswira na yanzu da kariyar wutar lantarki.Na...Kara karantawa -
Matsaloli a wurin gwajin majinin juriya na madauki
Lokacin da ma'aunin juriya na madauki (wanda ake kira ma'aunin juriya) wanda aka tsara bisa ga ƙa'idar ƙira ta gargajiya da aka gwada a cikin filin, an gano cewa akwai matsala gama gari.Lokacin da ma'aunin haɗin wutar lantarki na mai gwajin ya kasance a cikin mummunan lamba ko buɗaɗɗen kewayawa, gwajin...Kara karantawa -
Muhimmancin Gwajin Rigakafi a Ayyukan Kayan Wutar Lantarki
Domin rage hatsarori da kuma hana hatsarori, ya kamata a rika yi wa igiyoyin da ke aiki akai-akai don yin gwajin jure wa wuta.Ma'aunin gwajin ƙarfin wutar lantarki na DC na kebul na iya komawa zuwa ƙa'idodin aikin kebul masu dacewa.A ka'ida, da DC jure irin ƙarfin lantarki gwajin c ...Kara karantawa -
Nau'in gwaji na busasshen amfani da matakai
Nau'in gwajin busassun na'ura suna taka rawa sosai a cikin gwaje-gwajen gwaji mai ƙarfi, kuma suna ɗaya daga cikin na'urori da kayan aiki da aka fi yawan amfani da su ta hanyar mafi yawan masu gwadawa.Marubucin HV HIPOT zai gabatar da daidaitattun matakan gwaji na injinan gwajin busassun don taimaka muku inganta gwajin…Kara karantawa -
Yaya Aiki Dijital Grounding Down Lead Duniya Gwajin Ci gaba?
GDDT-10U gDigital Grounding Down Lead Earth Gwajin Ci gaba da gwajin ci gaba ne mai sarrafa kansa mai ɗaukar hoto wanda kamfaninmu ya haɓaka.Ana amfani da shi don auna ƙimar juriya na ci gaba tsakanin masu sarrafa ƙasa na kayan wuta daban-daban a cikin tashar.Ana sarrafa kayan aikin ta...Kara karantawa -
Me yasa transfoma ke buƙatar yin babban ƙarfin lantarki jure gwaji?
Lokacin da na'ura mai ba da hanya tsakanin hanyoyin sadarwa ke aiki a cikin grid na wutar lantarki, ba wai kawai yana ɗaukar aikin ƙarfin lantarki da na yanzu a cikin aiki na yau da kullun ba, har ma yana ɗaukar aikin nau'ikan ƙarfin lantarki na ɗan gajeren lokaci da na yanzu.Don haka, dole ne a kera shi kuma a kera shi don samun isasshen aminci da r...Kara karantawa -
Menene gwajin No-load na Transformer?
Gwajin no-load na taranfoma gwaji ne don auna asarar rashin kaya da halin yanzu na taransfoma ta hanyar amfani da ma'aunin wutar lantarki mai ƙima na sine wave wanda aka ƙididdige mitar daga iska ta kowane gefen na'urar, da kuma sauran iskoki a bude suke.A halin yanzu babu kaya ...Kara karantawa -
Tsare-tsare don aiki da majinin juriya mai ƙarfin wuta
Tsare-tsare don yin aiki da ma'aunin juriya mai ƙarfin lantarki: HV HIPOT GD3126A/GD3126B Gwajin juriya na Insulation na hankali 1. Yi aiki akan na'urori masu ƙarfi gwargwadon iko.Yi amfani da hanyoyin kullewa da suka dace.Idan waɗannan hanyoyin sun kasance ...Kara karantawa -
Mahimman hankali lokacin yin gwajin ƙarfin wutar lantarki na AC da DC
Abubuwan da ke da hankali lokacin yin gwaje-gwajen AC da DC masu ƙarfin lantarki 1. Mai canzawa da akwatin sarrafawa yakamata su sami ingantaccen ƙasa;2. Lokacin yin gwaje-gwajen high-voltage AC da DC, dole ne mutane 2 ko sama da su shiga, kuma a fayyace rabe-raben aiki a fili da hanyoyin juna sho...Kara karantawa -
Muhimmancin na'urar tsayayyar VLF don jurewar gwajin ƙarfin lantarki
A lokacin aikin lodi na janareta, rufin zai lalace a hankali a ƙarƙashin aikin filin lantarki, zafin jiki da girgizar injin na dogon lokaci, gami da lalacewa gabaɗaya da ɓarna kaɗan, yana haifar da lahani.Gwajin jurewar wutar lantarki na janareta...Kara karantawa -
Menene matsalar rashin ingantattun sakamakon ma'auni na babban janareta na DC?
Gwajin yabo na DC ta amfani da janareta na babban ƙarfin wutar lantarki na DC shine don yin nazari sosai kan ingancin rufin samfuran da aka gwada ta hanyar girman ɗigogin halin yanzu, canjin ɗigogi a yayin ci gaba da haɓakawa, da kwanciyar hankali na halin yanzu lokacin da th. ...Kara karantawa -
Yadda ake amfani da gwajin juriya na ƙasa
Juriya na ƙasa na'ura ce da ake yawan amfani da ita wajen gwajin masana'antar wutar lantarki, to ta yaya za a yi aiki da shi daidai?GDCR3000C Grounding Resistance Tester 1. Da farko, duba ko layin na yanzu, layin wutar lantarki da layin sadarwar ƙasa da ake amfani da su don gwajin a buɗe suke, ko tsatsa a ƙasa pi...Kara karantawa