GDPQ-300E Mai Binciken Ingancin Wuta
GDPQ-300E Power Analyzer na'urar gwaji ce mai ɗaukuwa ta gwaji da kuma nazarin ingancin aikin tsarin wutar lantarki.Yana sa ido da tattara bayanai a cikin dogon lokacin gudu, kuma yana ba da bincike mai jituwa da ƙididdigar ingancin iko.A halin yanzu, yana ba da kayan aikin bincike na bayanai, wanda ta yadda za a iya loda bayanan ma'auni zuwa PC.
●ARM da DSP, 16M byte ƙwaƙwalwar ajiya.
●Allon taɓawa, mafi sauƙi da dacewa.
●Aunawa da adana bayanai, ana iya loda su zuwa PC.
●Module tsarin, m zane da kuma abin dogara aiki.
●Sauƙi kuma dacewa haɓaka software.
●Cikakkun bayanai na ma'auni ta software na tantance ingancin ƙarfin wuta a cikin PC.
Ayyukan gano mita
| No | Abubuwa | Bayani |
| 1 | Wutar lantarki/Yanzu/Yawaita | Yana iya aunawa uku-lokaci ƙarfin lantarki, sifili line ƙarfin lantarki, uku lokaci halin yanzu, sifili line halin yanzu, mita. Za a iya nuna RMS, ƙimar kololuwa, rabon igiyar ruwa/kololuwa, tsarin igiyar ruwa, sigogin Trend da sauransu. |
| 2 | Hma'aunin igiyar wutament | Yana iya aunawa asali kalaman irin ƙarfin lantarki da halin yanzu da2-50 sau masu jituwaigiyar ruwa.Sakamakon ma'aunin ya haɗa da ingancin jituwa, abun ciki mai jituwa, abun ciki mai jituwa, da jimillar murdiya (THD).Histograms da trends zane-zane, da dai sauransu. |
| 3 | Ma'aunin Interharmonic | Yana iya auna 0.1 ~ 19.9 sau interharmonics na ƙarfin lantarki da halin yanzu.Sakamakon ma'auni ya haɗa da abubuwan haɗin haɗin gwiwa da ingantattun ƙididdiga na ƙasidar, ƙimar abun ciki na interharmonic da dai sauransu. zai iya nuna histograms, Trend Charts, da dai sauransu. |
| 4 | Ma'aunin wutar lantarki | Yana iya aunawa uku-lokaci hudu-waya / uku-lokaci uku-waya bayyane iko (lantarki), iko mai aiki (lantarki), Reactive iko (lantarki), ikon factor da dai sauransu., yana iya nunawaTrend Charts; iya aunawa bukata of 1, 5, 10, 15, 30 60 mintuna. |
| 5 | Ma'aunin rashin daidaituwa kashi uku | Ze iyama'auni uku-lokaci hudu-waya / uku-lokaci uku-waya tsarin lantarki tsarin lantarki da halin yanzu tabbatacce jerin bangaren, korau jerin bangaren, sifili bangaren, korau jerin rashin daidaituwa digiri, sifili rashin daidaituwa digiri;zango kusurwa uku na ƙarfin lantarki da halin yanzu,vector, Trend zane-zane. |
| 6 | Flicker | Minti 1 flicker, minti 10 gajeriyar flicker, tsawon awanni 2 |
| 7 | Voltage Kumburi / Dip / Katsewa | Gano kumarajistan ayyukan ƙarfin lantarki kumbura, sags da katsewa abubuwan da suka faru. |
| 8 | Stura halin yanzu | Gano da rajistan ayyukan karuwa abubuwan da ke faruwa a yanzu |
| 9 | Ƙarfin masu jituwa | Za a iya gano 2 ~ 30 sau Harmonic iko, na iya nuna histogram, Trendzane-zane, da dai sauransu. |
| 10 | Ƙarfin wutar lantarki | Cauna saurin canjin iko (aiki, mai amsawa, ikon bayyane) gwargwadon lokacin da aka saita (minti 1 ~ 5) |
| 11 | Masu wucewa | Cgano ƙarfin lantarki yana wucewa fiye da 20 micro seconds |
| 8 | Rikodin kulawa | Yana iya yin rikodin sigogin ingancin wutar lantarki na dindindin na dogon lokaci, gami da ƙarfin lantarki / halin yanzu / mitar, jituwa, iko, rashin daidaituwa na matakai uku, jujjuyawar / flicker, kuma ana iya daidaita tazarar rikodi daga sakan 3 zuwa mintuna 30. |
| 9 | Digital oscilloscope | Duba siginar sigina / sigina na yanzu |
Kowane ma'aunin daidaito don ayyukan ganowa
| Abu | Auna kewayon | Auna daidaito | Magana |
| Voltage / halin yanzu /yawanci | Three lokaci irin ƙarfin lantarki: 1000V (tasiri darajar) ZWutar lantarki: 70V (ƙimar inganci) Three halin yanzu: 6000A (ƙimar inganci, 1000A firikwensin halin yanzu don zaɓi) ZEro line halin yanzu: 25A (tasiri mai inganci) FYawan aiki: 40-70Hz | Wutar lantarki:0.1% rdg±0.05% fs A halin yanzu: 0.2%rdg±0.05% fs Fbukata: karatu±0.01 Hz | HDa farko, muna amfani da mitar ƙarfin lantarki na lokaci azaman mitar awo |
| Ma'aunin igiyar ruwa masu jituwa | VHarmonic oltage: THD+Mahimmin igiyar ruwa+ 2-50 sau masu jituwa. CHarmonic na gaggawa: THD+Mahimmin igiyar ruwa+ 2-50 sau masu jituwa. | Ƙarfin wutar lantarki mai jituwa: Uh≥1% UN, ±5% ku; Uh<1% UN, ±0.05% UN Harmonic kalaman na yanzu: Ih≥3% IN, ±5% Ih; Ih<3% IN, ±0.15% IN | |
| Inter masu jituwaigiyar ruwaauna | Voltage masu jituwa: 0.1 ~ 19.9 sauInter harmonicigiyar ruwa . CHarmonic na gaggawa: 0.1 ~ 19.9 sauInter harmonicigiyar ruwa | Wutar lantarkiInter harmonickalaman: Uih≥1% UN,5% uh; Uih<1% UN,0.05% UN; A halin yanzuInter harmonickalaman: Ih≥3% IN,5% yi; Ih<3% IN,0.15% IN | |
| Poyar / Wutar lantarki | Aikon aiki: 700kVA Rkarfin aiki: 700kVAR Halin wutar lantarki: 0.00 ~ 1.00 Amakamashi mai aiki: 10000kWh APowerarfin wutar lantarki: 10000kVAh Rmakamashi mai aiki: 10000kVARh Amatsakaicin ƙarfin wutar lantarki: 0.00-1.00 | Aaiki: karatu±0.5% Abayyane: karatu±0.5% Mai da martani: karatu±0.5% Power factor: karatu±0.005 | |
| Trashin daidaito lokaci | Frashin ƙarfi irin ƙarfin lantarki: 1000V (ƙimar inganci) Fhalin yanzu mara ƙarfi: 6000A (ƙimar inganci) Fmitar mara nauyi: 40-70Hz Pamma kwana: 0-360degree UMa'auni: 0.0-100% | Vgirma: 0.1% rdg±0.05% fs Cgirma: 0.2%rdg±0.05% fs Fbukata: karatu±0.01 Hz Phas angle: karatu±0.3 digiri Vrashin daidaituwa mai girma: karatu±0.2% Crashin daidaituwa na gaggawa: karatu±0.2% | Anan, muna amfani da mitar ƙarfin lantarki na lokaci azaman jimlar mitar awo |
| Voltage Flicker | Minti 1 ya fizgo, gajeren lokaci flicker, dogon lokaci flicker | Minti 1 mai kyalli:±5.5% Minti 10 gajeriyar flicker:±5% Tsawon awanni 2 yana flicker:≤± 5% | |
| Ƙarfafa ƙarfin lantarki, tsoma da katsewa | Saka idanu da yin rikodin ƙarar wutar lantarki-lokaci ɗaya/multi-multi-multi-multi-multi-fase voltage, tsoma wutar lantarki da kashe wutar wucin gadi | Rabin raƙuman ruwa RMS, lokacin farawa, tsawon lokaci, kuskuren ƙarshen lokacin ± 10ms | Har zuwa 40 rikodin aukuwa |
| Ci gaba a halin yanzu | Saka idanu da yin rikodin magudanar ruwa-lokaci ɗaya/multi-multi-fase | Ƙimar rms rabin-wave, lokacin farawa, tsawon lokaci, kuskuren lokacin ƙarshen ± 10ms | Dakatar da aunawa lokacin ɗaukar wani taron |
| Ƙarfin igiyar ruwa mai jituwa | Jimlar lokutan ƙarfin jituwa: 1 ~ 30th Jimillar ƙarfin aiki mai jituwa:∑P Harmonic jimlar ƙarfin amsawa:∑Q Madaidaicin jituwa duka ikon aiki: +∑P Ikon aiki mara kyau: -∑P Madaidaicin jituwa jimlar ƙarfin amsawa: +∑Q Ikon amsawa mara kyau: -∑Q | Karatun ikon jituwa: ± 0.5% | |
| Ƙarfin wutar lantarki | Yana iya gano tsawon mintuna 1, 3, 5 na aiki, mai amsawa, bayyananniyar ƙimar ikon rabin igiyar ruwa, rikodin yanayin canjin wutar lantarki | Karanta ikon rabin-ƙara: ± 0.5% | |
| M | Matsalolin wutar lantarki dangane da ƙimar ƙima fiye da 120% | 1.tMafi ƙarancin lokacin abubuwan da za a iya aunawa ya wuce 20 micro seconds 2.yuwuwar kama taron 98.7% | Ana iya adana abubuwan 20 a cikin ma'auni ɗaya |
| Mrikodin rikodin | REcord sigogi sun hada da irin ƙarfin lantarki, halin yanzu, mita, ƙarfin lantarki / halin yanzu jituwa kalaman ( jimlar jitu + 1-25 sau masu jituwa), trashin daidaituwa na lokaci-lokaci;mai aiki / mai amsawa / bayyanannen iko, factor factor;jujjuyawar / flicker | Tazarar ajiyar bayanai: 3s ~ 30min Tazarar shine 3s, kuma jimlar lokacin kulawa shine 16h; Tsawon lokacin shine 30min, kuma jimlar lokacin sa ido shine 960h. | |
| DTsarin oscilloscope | Three lokaci irin ƙarfin lantarki, uku lokaci halin yanzu, sifili line ƙarfin lantarki da sifili halin yanzu kama igiyar ruwa form | Max.mitar samfurin: 200kHz Min.mitar samfur: 100Hz |
●Madauki na shigar da siginar wutar lantarki:
Samun damar kai tsaye, rashin ƙarfi na shigarwa: 1MΩ, 20pF
Ma'auni: ƙimar ƙarfin lantarki mai tasiri 1000V
Amfanin wutar lantarki: ƙasa da 0.5VA/lokaci
●Madauki na shigarwa na yanzu:
Shiga kai tsaye
Ƙimar aunawa: Ƙimar mai tasiri na yanzu 1A, 5A, 10A, 100A, 500A, 1000A, 3000A (zaɓa madaidaicin firikwensin halin yanzu)
Amfanin wutar lantarki: Kasa da 0.5VA/lokaci
●Auna kewayon mitar sigina: 40Hz-70Hz
●Nuni allon: 5.7 inch 640 * 480 LCD launi tare da allon taɓawa
●Adana ƙwaƙwalwar ajiya: 128M byte FLASH
●Wurin ajiya na waje: USB (toshe cikin faifan USB)
●Samar da wutar lantarki: Li-baturi mai caji, 5-6hours lokacin aiki don cikakken caji
●Wutar lantarki: AC100-240V/DC 16.8V-1A adaftar wutar lantarki/caja
| Mai gwadawa | 1 saiti |
| 5A matsi na yanzu | guda 3 |
| Wutar gwajin wutar lantarki | guda 1 |
| Adaftar wutar lantarki | guda 1 |
| Maida waya | guda 1 |
| QC wuce | 1 kwafi |
| Littafin mai amfani | 1 kwafi |
| Rahoton gwajin masana'anta | 1 kwafi |
| Jerin kaya | 1 kwafi |