GDTG-600A Cable Fault Locator shine kayan aikin buɗaɗɗen iska mai ɗaukuwa wanda ke aiki akan TDR da hanyoyin gada, yana ɗaukar fasahar micro-electronics na ci gaba.An ƙera shi don gano sahihan abubuwan kuskure a cikin irin waɗannan igiyoyi kamar kebul na filastik na sadarwa ko wayar da aka rufe da gubar mai amfani, yayin da kurakuran sun haɗa da karyewa, gaurayawa, ƙasa, gurɓataccen rufi, ko rashin haɗin kai.Kayan aiki ne mai dacewa da kwanciyar hankali don ma'aikacin bude-iska don inganta ingantaccen aiki;Bugu da ƙari, ana iya amfani da shi don aikin kewayawa don gwada gwajin kadarorin lantarki na kebul.
-
GDJF-2006 Mai Nazari na Sashe na Fuska
GDJF-2006 Dijital Partial Discharge Detector ana amfani dashi ko'ina don gano ɓarna juzu'i na kayan aikin wuta mai ƙarfi kamar su masu wutar lantarki, mai canza kayan aiki, mai fashewar kewaye HV, mai kama Zinc oxide surge arrester, igiyar wuta.Hakanan yana iya yin gwaje-gwajen nau'in da sa ido kan aikin rufewa.
-
GDPD-3000C Mai Gano Sashe Mai Rarraba
GDPD-3000C Portable Ultrasonic Partial Discharge Detector yana amfani da na'ura mai kwakwalwa ta girgije da fasaha ta atomatik don cimma ma'aunin siginar fitarwa, rikodi, watsawa, ajiya, bincike da musayar, samar da goyon baya na fasaha mai karfi don aunawa a kan-site na fitarwa.
-
Gdcl-v 20kv / 10ka nuna hade hade da kalaman gwajin fasaha na gwaji
Kayan aikin yana daidai da buƙatun gwajin igiyar igiyar ruwa na tsarin rarraba wutar lantarki mai ƙarancin ƙarfi na samfurin SPD II, yana ba da damar samar da wutar lantarki mai ƙarfi (1.2 / 50μs) da halin yanzu (8/20μs), ana amfani da shi don gwajin sa na III da iyakance gwajin ƙarfin lantarki. na SPD da aka gyara.
-
GDP-311CAW 3-in-1 SF6 Na'urar Analyzer
GDP-311PCAW SF6 ingancin iskar gas na'ura ce mai ɗaukuwa wadda aka ƙera don auna tsaftar iskar SF6, raɓa, abun ciki, abun ciki na CF4 da abun cikin iska.
-
GDQC-16A(mini) SF6 Vacuum Pumping da Cika Na'urar
GDQC-16A Gas Vacuum Pumping da Cika Na'urar ana amfani da shi azaman kayan taimako na kayan aikin gas GCBT, GIS, SF6 yayin shigarwa, gyarawa da gyarawa a cikin kamfanonin samar da wutar lantarki daban-daban, kamfanonin watsa wutar lantarki, kamfanonin wutar lantarki, watsa wutar lantarki mai ƙarfi, SF6 gas masana'antar kera wutar lantarki da sauran sassa.
-
GMDL-02A HV Na'urar Analog Mai Breaker
GMDL-02A ana kera na'urar simintin keɓan wutar lantarki mai ƙarfi ta amfani da ƙa'idodin babban filin da za a iya tsara shirye-shiryen ƙofa, na'urorin lantarki masu ƙarfi tare da kariya, da sauransu.
-
GDYZ-302 Mara waya ta Zinc Oxide Surge Arrester Gwajin
GDYZ-302 Zinc Oxide Arrester Live Tester kayan aiki ne na musamman da ake amfani dashi don gwada aikin wutar lantarki na Zinc Oxide Arrester.
-
GDF-3000 DC Mai gano Laifin Tsarin Duniya
A cikin tsarin DC, akwai kurakuran ƙasa da yawa da suka haɗa da laifin ƙasa kaikaice, kuskuren duniya wanda ba ƙarfe ba, laifin madauki, kuskuren ƙasa mai kyau da mara kyau, ingantacciyar ma'auni mara kyau da kuskuren ƙasa, kuskuren duniya da yawa.
-
GDCR1000C Gwajin Jeri na Mataki mara lamba
GDCR1000C, GDCR1000D mara lamba gwajin lokaci ne babban ci gaba a cikin al'ada al'ada tsarin gane jeri tsari.
-
GDYM-3M Multi-aikin Electric Energy Meter Calibrator
Ana iya auna kurakurai, ƙarfin lantarki, halin yanzu, mai aiki da ƙarfin amsawa, lokaci, mita, da ƙarfin wuta lokaci guda, haka nan za a nuna siffa vector da sakamakon wayoyi.
-
GDPQ-5000 Mai Binciken Ingancin Wuta
GDPQ-5000 Power Quality Analyzer babban kayan aikin gwaji ne a hankali wanda kamfaninmu ya haɓaka kuma an tsara shi musamman don gwajin filin na matakai uku, ayyuka da yawa da fasaha, taƙaitaccen aikin injin injin.