  • GDP-713PM SF6 Mai Gwajin Raɓar Gas (Tsarin Madubi Mai sanyi)

    GDP-713PM SF6 Mai Gwajin Raɓar Gas (Tsarin Madubi Mai sanyi)

    GDP-713PM Madubin Chilled Mai ɗaukar nauyi SF6 Gas Dew Point Gwajin an ƙera shi na musamman don gano ƙarancin iskar gas na SF6.Cikakken haɗin haɗin firikwensin raɓa mai inganci da fasaha na sarrafa lantarki mai fasaha ya sa ya sami nasarar amfani da ma'aunin ma'aunin raɓa a ƙarƙashin yanayi daban-daban na muhalli.

    Ma'aunin raɓa yana dogara ne akan ƙa'idar madubi mai sanyi.Turin ruwan da ke cikin iskar gas ɗin da aka auna yana murƙushewa cikin ruwa ko sanyi akan saman madubi ta hanyar sanyaya wutar lantarki ta semiconductor sanyi.Lokacin da aka kai ma'aunin ruwa mai kashi biyu na gas, ana auna zafin saman madubi a wannan lokacin, wato wurin raɓa ko sanyi.

    Idan aka kwatanta da sauran nau'ikan mitar raɓa, mitar raɓar madubi mai sanyi tana auna zafin raɓa daidai, kuma a lokaci guda yana da halaye na maimaita ma'auni mai kyau, tabbataccen sakamakon aunawa, da sauƙin aiki.

    GDP-713PM šaukuwa sanyaya Hanyar SF6 gas dew batu mita ne wani misali kayan aiki don zafi auna a filayen wutar lantarki, gas, meteorology, lantarki, man fetur, sinadaran masana'antu, auna, da dai sauransu Yana da manufa zabi don kafa wani zafi misali. na'urar.

  • GDP-8000CM SF6 Mai Gwajin Raɓar Gas (Tsarin Madubin Chilled)

    GDP-8000CM SF6 Mai Gwajin Raɓar Gas (Tsarin Madubin Chilled)

    GDP-8000CM Maɗaukakin Chilled Mirror SF6 Gas Dew Point Tester an tsara shi musamman don gano ƙarancin iskar gas na SF6 da aka yi amfani da shi a duk yankin zafin jiki na masana'antar wutar lantarki, wanda ya dogara da sanyin Stryn da ƙa'idar auna madubi mai sanyi.

  • GDQC-55A SF6 Iskar Gas da Injin Ciki

    GDQC-55A SF6 Iskar Gas da Injin Ciki

    GDQC-55A SF6 Gas Vacuuming da Filling Machine ana amfani dashi galibi don shigarwa, aiki, da kuma kula da 35kV ~ 220kV yumbu ginshiƙi SF6 masu rarraba da'ira, masu canji da sauran kayan aikin lantarki na SF6.Na’ura ce mai kamshi, wacce aka dora a kan katafaren karfe mai karfi, kuma tana tafiya cikin walwala ko da a kan titin tsakuwa.

    Ya dace da kayan lantarki na SF6, masana'antar GIS da cibiyar bincike.

  • Tsarin Gwajin Fitar Sashe na GIT

    Tsarin Gwajin Fitar Sashe na GIT

    Ana amfani da jerin GIT don babban ƙarfin lantarki, babban ƙarfin kayan aikin wutar lantarki na GIS wanda aka keɓe don gwajin ƙarfin lantarki, gwajin fitarwa na ɓarna da gwajin daidaiton GIS, wanda ya dace da tashar GIS, mai kera kayan wutar lantarki na GIS, masana'anta na nau'in kwandon lantarki.

     

     

     

     

     

     

  • GDSL-A Saitin Gwajin allura na Farko na Farko na 3-A atomatik tare da Gwajin Zazzabi

    GDSL-A Saitin Gwajin allura na Farko na Farko na 3-A atomatik tare da Gwajin Zazzabi

    GDSL-A Series 3-Primary Injection Test Set with Temperature Test shine ingantacciyar kayan aiki don gwada babban na'urar a cikin masana'antar wuta da lantarki, ana amfani da su a cikin wutar lantarki, tashoshin rarraba wutar lantarki, masana'anta na lantarki da cibiyoyin bincike, tare da fasali. na ƙananan girman, nauyin nauyi, sauƙin amfani da kulawa.

     

     

     

     

     

  • GDCY Tsarin Gwajin Wutar Lantarki (100kV-7200kV)

    GDCY Tsarin Gwajin Wutar Lantarki (100kV-7200kV)

    Tsarin Gwajin Wutar Lantarki ana amfani dashi galibi don aiwatar da cikakken gwajin ƙarfin walƙiya na walƙiya, gwajin tsinkewa da sauya gwajin motsawa akan na'urorin HV kamar su masu canza wuta, mai kamawa, insulators, bushings, capacitors, da masu sauyawa.Yana iya haifar da daidaitaccen igiyar walƙiya, igiyar juyawa, igiyar sarewa tare da faffadan ƙarfin lantarki da ƙarfi.

     

     

     

  • Tsarin Gwaji na Sashe na GDYT

    Tsarin Gwaji na Sashe na GDYT

    An yi amfani da shi sosai a masana'antar lantarki, sassan sarrafa wutar lantarki, cibiyoyin bincike da jami'o'i.

     

     

     

  • GDBT-1000kVA Transformer Test Bench

    GDBT-1000kVA Transformer Test Bench

    Tsarin gwaji na GDBT na Transformer na iya gudanar da duk gwaje-gwaje na yau da kullun don masu canji, gami da No-load da gwajin lodi, Gwajin ƙarfin lantarki da aka ƙirƙira, gwajin jurewar wutar lantarki, gwajin fitarwa na juriya, gwajin juriya na DC, gwajin juzu'i, gwajin tashin zafin jiki da sauransu.

  • GDYB-S20 Tsarin Gwajin Mita Makamashi Mataki na Uku

    GDYB-S20 Tsarin Gwajin Mita Makamashi Mataki na Uku

    Jerin GDYB Uku Daidaita Mahimmanci Multi-Ayyukan Tsarin Gwajin Makamashin Makamashin Wutar Lantarki yana da ingantaccen ingantaccen tsarin lantarki na ƙarni na uku wanda zai iya tsara tsarin gwajin aikin mita uku na lantarki bisa ga sabbin ƙa'idodi da ƙa'idodi na ƙasa.

     

  • GDHX-9500 Mai Gano Matsayi

    GDHX-9500 Mai Gano Matsayi

    GDHX-9500 Fase Detector ana amfani dashi galibi a cikin layukan wutar lantarki, daidaita tsarin lokaci da lokaci a cikin tashar, tare da manyan ayyuka gami da duba lantarki, daidaita lokaci da ma'aunin tsarin lokaci.

  • GDHX-9700 Mai gano lokaci

    GDHX-9700 Mai gano lokaci

    GDHX-9700 Fase Detector an fi amfani dashi a cikin layin wutar lantarki, lokaci, da daidaita tsarin lokaci a cikin tashar, tare da manyan ayyuka ciki har da binciken lantarki, daidaitawar lokaci da ma'aunin tsarin lokaci.

  • GDND-800 Mai Gwajin Daskarewa

    GDND-800 Mai Gwajin Daskarewa

    Mai gwada daskarewa mai mai canzawa yana da halaye na ƙirar tsari mai kyau da tsarin masana'antu na musamman.Ya dace da ka'idodin GB/T 3535 da GB/T510 kuma ana amfani da shi don tantance wuraren zub da man fetur.