GDB-D Transformer Juya Ratio Gwajin
GDB-D Mai jujjuya juzu'i mai jujjuyawa an ƙera shi ne don mai canzawa matakai uku a cikin tsarin wutar lantarki kuma musamman don nau'in wutar lantarki na nau'in Z da sauran na'urori masu taswira tare da manyan abubuwan da ba su da nauyi.
-
GDB-H Mai Canjin Hannu ta atomatik Yana Juya Gwajin Ratio
Yana iya auna jujjuyawa daidai gwargwado, rukuni da kusurwar lokaci, wanda ya dace da kowane nau'ikan tasfoma kamar su na'urorin wuta na nau'in Z, na'urar gyara tawul, injin tanderu na wutar lantarki, na'urorin canza yanayin lokaci, na'urar wutar lantarki, scott da invert-scott.
-
GDB-IV Mai Canjawa Mataki Na Uku Yana Juya Gwajin Ratio
Tsarin wutar lantarki na ciki a cikin ma'ajin yana haifar da wutar lantarki mai kashi uku ko biyu, wanda ke fitowa zuwa babban ƙarfin wutar lantarki na na'urar.Sa'an nan kuma babban ƙarfin lantarki da ƙananan ƙarfin lantarki ana yin samfurin lokaci guda.A ƙarshe, ƙungiyar, rabo,kuskure,kuma ana ƙididdige bambancin lokaci.
-
GD6900 Capacitance da Factor Factor Factor
GD6900 yana auna ƙarfin ƙarfin da kuma asarar dielectric (tgδ) na babban ƙarfin lantarki na kayan lantarki.Yana da tsarin da aka haɗa, ginanniyar gadar gwajin hasarar dielectric, samar da wutar lantarki mai sauƙin daidaitawa, haɓaka mai canzawa da SF6 daidaitaccen capacitor.
-
Gwajin Juriya na GDZRC na DC (GDZRC-10A)
GDZRC-10A
GDZRC jerin DC mai juriya juriyaan tsara shi don auna juriyar DC na inductivena'urori, irin su taransfoma da wutar lantarki.
Yana da siffofi na ma'auni mai sauri, ƙananan girmanda high daidaito na ma'auni, wanda shi ne manufa kayan aikina auna wutar lantarki winding da DC juriya nababban iko inductance kayan aiki. -
GD6800 Capacitance da Factor Factor Factor
GD6800 isa full atomatik 10KV insulation power factor/dissipation factor (tan∂) gwajineran ƙera shi don kimanta yanayin rufin lantarki a cikin na'urori masu ƙarfin lantarki kamar su masu canza wuta, bushings, na'urorin kewayawa, igiyoyi, masu kama walƙiya da injin juyawa.
-
GDZRS-20A Mai Gwajin Juriya na Mataki Uku na DC
Wannan gwajin saurin juriya na DC (wanda ake kira da DC winding resistance tester) shine sabon samfuri na zamani don auna juriyar DC na masu taswira.An inganta shi don auna juriya na DC na iska mai hawa uku na manyan injina.Ana iya gwada juriyar DC na iska mai hawa uku na taswira lokaci guda.Don wutar lantarki mai sarrafa wutar lantarki, ba lallai ba ne a sauke mai canza famfo kai tsaye, kuma lokacin aunawa shine kashi ɗaya bisa uku na ma'aunin al'ada guda ɗaya, wanda zai iya rage yawan lokacin aiki da ƙarfin aiki.Mitar juriya kai tsaye tana ɗaukar babban allo mai nunin kristal na ruwa, duk ƙirar sinawa mai hoto, bayyananne da fahimta, kuma aikin yana da sauƙi.Kuma sanye take da firintar panel da ƙwaƙwalwar ajiya mai ƙarfi mara ƙarfi, zaka iya adanawa da buga sakamakon auna cikin sauƙi.Bayanan gwajin sun tsaya tsayin daka, da sauri kuma ana iya maimaita su, kuma shine mafi kyawun zabi don auna juriya na DC na masu canji a wurin.
-
GD6100 Insulation Oil Tan Delta Tester (Mai Gwajin Fatar Mai)
GD6100 babban madaidaicin kayan aiki ne don gwada kusurwar asarar dielectric da juriya na ƙarar mai ko wasu ruwa mai rufewa.
-
GDOT-80A IEC Standard Insulation Breakdown Tester 80kV
Akwai adadi mai yawa na kayan lantarki a cikin tsarin wutar lantarki, tsarin layin dogo da manyan ma'adanai da masana'antu na petrochemical, rufin su na ciki galibi rufi ne mai cike da mai.Ƙarfin dielectric na insulating mai gwaji ne na yau da kullun na wajibi.Don biyan bukatun kasuwa, kamfaninmu ya haɓaka kuma ya samar da jerin ƙarfin gwajin ƙarfin dielectric mai dielectric bisa ga ma'auni na ƙasa GB/T507-2002(IEC156), daidaitaccen DL429.9-91 da sabuwar masana'antar wutar lantarki. DL/T846.7-2004.Wannan kayan aikin yana ɗaukar microcomputer mai guntu guda ɗaya a matsayin jigon, yana gane duk aikin sarrafa kansa na gwajin, yana da ma'aunin ma'auni mai girma, yana inganta ingantaccen aiki sosai, kuma yana rage ƙarfin aiki na ma'aikata sosai.A lokaci guda, kayan aiki yana da ƙananan bayyanar kuma ya dace don ɗauka.
-
GDOT-80A Mai gwada Mai Insulation
Da fatan za a karanta littafin aiki a hankali kafin aiki.
Da fatan za a bincika idan mai gwadawa yana da alaƙa da ƙasa sosai kafin gwaji.
An haramta motsa ko ɗaga murfin gwaji yayin gwajin don guje wa rauni ta babban ƙarfin lantarki.Dole ne a kashe wutar lantarki kafin maye gurbin samfurin mai. -
GDKC-5000 Mai Canjawa Akan Maɓallin Canjin Maɓallin Load
GDKC-5000 Transformer Akan Load Tap Mai Canja Mai Canjawa na iya auna daidai lokacin wucin gadi, tsarin igiyar ruwa na wucin gadi, juriya na wucin gadi, aiki tare na matakai uku da sauran sigogi na mai canza tap.Na'ura ce da ta dace don gwada mai sauya tafsiri.Ya cika buƙatun duba jerin ayyuka na mai canza famfo da auna lokacin sauyawa.
-
GDBT-1000kVA Transformer Test Bench
Tsarin gwaji na GDBT na Transformer na iya gudanar da duk gwaje-gwaje na yau da kullun don masu canji, gami da No-load da gwajin lodi, Gwajin ƙarfin lantarki da aka ƙirƙira, gwajin jurewar wutar lantarki, gwajin fitarwa na juriya, gwajin juriya na DC, gwajin juzu'i, gwajin tashin zafin jiki da sauransu.