GD4136H Cable Fault tsarin shine kayan aiki mai mahimmanci don kula da kowane nau'in igiyoyi.Yana amfani da hanyoyi daban-daban na ganowa don gwada kurakuran na USB, wanda ya dace da matakan ƙarfin lantarki daban-daban da igiyoyin sadarwa.
Tsarin ya ƙunshi raka'a a ƙasa:
1.GD-2131H Mai Haɓakawa
2.GD-4132 Cable Fault Locator
3.GD-4133 Multi-pulse Cable Fault Detector
4.GD-4133S Multi-pulse Coupler
5.Sauran kayan haɗi
Saukewa: GD-2131H

Ana amfani da shi don haifar da motsin HV lokacin amfani da hanyar walƙiya mai ƙarfi don gano kuskuren impedance.
●Ƙarfin ƙonawa mai ƙarfi, ƙarfin max.ƙonawa shine 1000W, rushewaZa a iya ƙone batu a cikin ɗan gajeren lokaci kuma an rage juriya na raguwa.
●Idan aiki tare da GD-4133 Cable Fault Tester, akwai hanyoyi guda biyu:
a.Ƙananan bugun jini: Idan kawai ta amfani da GD-4133, buɗe kewayawa da ƙananan kurakuran ƙasa na kebul za a iya gano su, kuma ana iya auna tsayin kebul ko kuma ana iya gano saurin igiyar kebul.
b.Babban walƙiya mai walƙiya: Ana yin samfur ɗin nau'in nau'in ƙarfin ƙarfin bugun bugun bugun jini na kuskure ta hanyar fitar da tazara, wanda zai iya gano tazarar kuskure.
●Ƙirƙirar motsawar ƙayyadaddun mitoci.Idan aiki tare da GD-4132 Cable Fault Locator, akwai ayyuka masu zuwa:
a.Mitar sauti: gano wuri mai tsayi, kurakuran filasha.
b.Don nuna hanyar kebul, gano kebul na musamman.
c.Don rushewar ƙarfe (mataccen ƙasa), ta amfani da ma'aunin filin maganadisu don gano daidai.
●Hakanan ana iya amfani dashi a gwajin jurewar DC HV.
●Wutar lantarki ta shigarwa: AC 220V, 50Hz
●Wutar lantarki mai fitarwa: DC 0-32kV (daidaitacce)
●rated ikon: 2kVA
●Matsakaicin makamashi: 2048J, 4uF
●Wutar lantarki ta DC: 32kV
●DC flashover halin yanzu: 63mA
●Max.impulse na yanzu: 500mA
●Hanyar fitarwa: DC HV, lokaci ɗaya, sake zagayowar
●Lokacin fitar da zagayowar: 3-6 seconds
●Yanayin muhalli: 0-40 ℃
●Humidity: <75% RH
●Tsayi: <1000m
●Insulation matakin: A
●Girma: 430*540*410mm
●Nauyi: kimanin 31kg.
Ciki har da babban naúrar, acoustic da firikwensin maganadisu, belun kunne na hana amo da caja.
Ya dace don gwada kowane nau'in kebul na wutar lantarki tare da madugu na ƙarfe.
Babban aikinsa shine gano madaidaicin wurin rufewa, gano kewaye da zurfin kebul na wutar lantarki.

●Acoustic Magnetic karba a lokaci guda.
●Ƙarfin ƙarfin hana tsangwama.
●Tare da belun kunne na hana surutu.
●320*240 LCD nuni.
●Gina babban ƙarfin Li-batir, tare da caja mai sauri.
●Nunin siginar sauti da Magnetic nuni, sigina da amo yana da sauƙin rarrabewa.
●Yin amfani da siginan kwamfuta don auna jinkirin sauti da maganadisu, ƙayyade maƙasudin kuskure daidai.
●Dangane da polarity na farko na magnetic.waveform, yana iya ganowa da gano hanya.
1. Aikin gano wuri
a.Ƙungiyar watsa siginar Acoustic: mitar cibiyar 400Hz, bandwidth 200Hz
b.Siginar riba: 80dB
c.Daidaitaccen wuri: 0.1m
2.Samar da wutar lantarki
a.Gina-batir Li-batir, ƙarancin ƙarfin lantarki 7.4V, ƙarfin 3000mAH.
b.Amfani da wutar lantarki: 300mA, ci gaba da aiki lokaci 9hours.
c.Caja: shigar da AC220V± 10%, 50Hz.Fitowar ƙima ta 8.4V, DC 1A
d.Lokacin caji: 4 hours
3. Girma: 270mm*150mm*210mm
4. Nauyi: 1.5kg.
5. Amfani da yanayin
Zazzabi -10 ℃ - 40 ℃, zafi 5-90% RH, tsawo <4500m

GD-4133 Cable Fault Detector Ana amfani dashi don aunawa
nisa tsakanin kuskuren na USB.Yana da sauƙi don
aiki da kuma tare da sada zumunci dubawa.
Ana iya amfani da shi kaɗai a ƙarƙashin yanayin bugun jini mara ƙarfi.U
A karkashin yanayin bugun jini na yanzu, yana buƙatar yin aiki tare da GD-2131
babban ƙarfin lantarki janareta.A ƙarƙashin mahara bugun jini yanayin, GD-4133S
ya kamata a yi aiki tare.Bayan gano wuri mai nisa, GD-4132 ya kamata a yi amfani da mai gano kuskure don nuna kuskure.Ana iya haɗa waɗannan samfuran cikin
saitin babban aiki da tsarin gwajin kuskuren na USB.
●7inch LCD allo, sada zumunci dubawa.
●Hanyar gano nesa da yawa:
Hanyar bugun jini mara ƙarfi: ya dace da gano ƙarancin juriya, ƙarancin kewayawa, kuskuren kewayawa.Hakanan za'a iya amfani dashi a ma'aunin tsayin kebul, tsaka-tsakin haɗin gwiwa, haɗin T, da haɗin ƙare na USB.Hakanan ana iya amfani da wannan hanyar don gyara saurin igiyoyin ruwa.
Hanyar halin yanzu pulse: Ya dace da auna nisa na babban juriya, kuskuren lalacewa.Yin amfani da na'ura mai haɗawa na yanzu don tattara sigina daga waya ta duniya, yana sa mai amfani yayi nisa da babban ƙarfin lantarki.Wannan hanyar tana da aminci kuma abin dogaro.
Yawan bugun jini: hanyar ci gaba don auna nisa.Tsarin igiyar ruwa yana da sauƙin ganewa kuma daidaito yana da girma.
●Samfurin 200MHz na ainihi.Max.0.4m ƙuduri ƙuduri.Yana da ƙananan mataccen yanki kuma na musamman don gajeriyar kebul ɗin kuma kusa da kebul na kuskure.
●Taba allo kuma danna aikin maɓalli
●Kwafin PIP (pic.ajiya na wucin gadi)
Za a sami babban taga kuma tagogin ajiya na wucin gadi uku za su iya duba nau'ikan igiyoyi uku tare.
●Ginin tsarin aiki
Gudanar da software na musamman don haɓaka software, wariyar ajiya da mayarwa.
●Ayyukan sikelin
Wurin farawa, lambobi 10, laifin kebul ɗaya da cikakken tsayi ɗaya na iya zama saiti.
Nuna ma'auni da tsarin gwaji tare
●Waveform ajiya da sadarwa tare da kwamfuta.
Ciki ajiya na waveforms.
Tare da USB, don saukewa ko loda bayanai
Sadarwa tare da kwamfuta
●Gudanar da wutar lantarki
Hasken baya yana rauni idan babu aiki a cikin mintuna 2 kuma a kashe wuta cikin mintuna 10 idan babu aiki.
Batir Lithium-ion Polymer da aka gina a ciki.
Lokacin aiki shine har zuwa awanni 5 don kowane amfani.
Harka mai ƙarfi, mai sauƙin ɗauka.
| Hanyoyin ganowa | Hanyar ƙwanƙwasa ƙarancin wutar lantarki Ƙaddamar da hanyar halin yanzu Hanyar ƙwanƙwasa da yawa idan ta dace da GD-4133S |
| Max.Mitar samfur | 200 MHz |
| Riba iyaka | 0-70dB |
| Ƙarƙashin ƙarfin wutar lantarki mai ƙarfi | 30V |
| Matsakaicin ƙuduri | 0.4m ku |
| Max.Gano kewayon | 100km |
| Yankin matattu | 2m |
| Baturi | Nickel-metal hydride baturi mai caji, lokacin juriya sama da 5 hours |
| Sadarwar sadarwa | USB |
| Tushen wutan lantarki | Shigar da AC220V, 50Hz, 2A na yanzu, cajin sa'o'i 8 |
| Dim. | 274×218×81mm |
| Nauyi | 3.5kg |
| Yanayin Aiki | -10 ℃-40 ℃ |
| Danshi | 5-90%RH |
| Girma | <4500m |

Yana aiki tare da GD-4133 Cable Fault Detector,ana amfani da shi don gano kuskuren yatsa mai girma, kuskuren flashover,low impedance ƙasa da bude kewaye kuskuren ikon igiyoyi.
GD-4133S ya ba da siginar haɗaɗɗen bugun jini don GD-4133 daware shi daga babban ƙarfin lantarki kayan aiki.
●Amfani da fasaha mafi ci gaba na ma'aunin bugun jini da bugun jini.Siffar igiyar igiyar igiyar ruwa ta fi sauƙi a gano.
●Tare da kariya ta HV mai aminci, da'irar aunawa da babban ƙarfin ƙarfin kuzari an keɓe ta hanyar lantarki.
●Sauƙaƙe wayoyi, aminci kuma abin dogaro.
●Wutar lantarki: 300V(PP)
●Izinin shigar da ƙarfin ƙarfin kuzari: <35kV
●Ƙarfin shigar da aka yarda da shi: <2000J
●Shigar da wutar lantarki: 220V AC, 50Hz
●Girma: 560*230*220mm
●Nauyi: 7kg.