GDCF-900T Tsarin Gano Laifin Kebul ɗin Mota
Ana amfani da tsarin gano ma'aunin gano abin hawa don daidaita yanayin kuskuren Cable (ƙonawa), Pre-Location, Wurin Hanya, Nuni da Gwajin HV & LV igiyoyi & girma dabam dabam.Saitin ya dace don aiwatar da abubuwan da aka ambata a sama akan igiyoyin wutar lantarki na matakan ƙarfin lantarki daban-daban musamman 33KV, 11KV, 415V da igiyoyi masu sarrafawa tare da maki 1.1 KV.Za a yi amfani da saitin don nau'ikan kebul wato XLPE, PVC, PILC tare da jagoran Al / Cu.Ana ajiye igiyoyin a ƙarƙashin ƙasa (ƙarƙashin ƙasa ta fili, ramuka, ko saman RCC, Hakowa a tsaye a cikin bututun HDD), sama da ƙasa ko wani yanki a ƙarƙashin & wani yanki sama da ƙasa tare da matsakaicin tsayin kebul a kusa da 25Km.
Mai gano kuskuren kebul ɗin ya dace don gano kuskure da kuma nuna nau'ikan kurakuran na USB masu zuwa.
●Babban juriya
●Ƙananan juriya
●Laifin walƙiya na wucin gadi.
●Wurin Laifin Sheath
●Tsarin yana amfani da bugun jini da yawa (hanyar tunani ARC), bugun bugun jini sau uku, hanyar motsa jiki, hanyar walƙiya, hanyar TDR don aiwatar da ma'aunin kowane nau'in kuskuren na USB.
●Yana amfani da hanyar maganadisu mai sauti don gano daidaitattun wuraren da ba daidai ba.
●Yana amfani da ƙa'idar induction electromagnetic don bin diddigin kebul ɗin da ba a san shi ba da gano zurfin kebul ɗin.
●Gane da huda gunkin igiyoyi.
●Gano wuri kuma auna kumfa na USB.
Tsarin gwajin kuskuren na USB wanda aka ɗora a cikin abin hawa yana amfani da tsari na tsari da ƙirar ɗan adam don gano babban laifin insulation na igiyoyin wutar lantarki na 33KV, 11KV da 415V, gano kuskuren wurin kube na waje, madaidaicin matakin yanke hukunci, gwajin hanya, gano rayuwa, huda aminci. , DC juriya cewa kowane nau'in kayan gwaji, kayan rarraba wutar lantarki, kayan haɗi da kayan aikin taimako da ake buƙata ana shigar dasu akan motocin da aka gyara na musamman.
Duk tsarin gwajin yana da lafiya kuma yana rufe, kuma ayyukan gwajin sun bambanta kuma sakamakon gwajin daidai ne.
●Motar ta ƙunshi sassa uku: taksi, ɗakin aiki da sashin kayan aiki.
●Tsarin na'urar wasan bidiyo mai ma'ana yana da ma'ana, kuma gwajin rufin kebul, yanke hukunci na kuskure, da ma'aunin tazarar kuskure ana iya kammala shi gaba ɗaya a cikin abin hawa.
●Mai watsa shiri na kuskuren na iya kammala ma'aunin tazarar tazarar kuskuren kebul kuma zai iya matsa matsayi ta atomatik.
●An ƙera ɗakin kulawa tare da ɓangaren ƙarfin ƙarfin ƙarfin ƙarfi mai zaman kansa, LCD yana nuna ainihin lokacin halin yanzu da ƙarfin lantarki, kai tsaye cikin hikima kammala aikin ƙarfin lantarki da fitarwa.
●Gano kebul, mai gwajin hanya an saka shi a cikin dakin aiki.
●Teburin aiki an yi shi da resin epoxy don sa gaba ɗaya ya yi kyau da kyau.An ƙera aljihunan kayan aiki tare da kera karfe da makullin dogo masu ɗaukar sauti.Yana da ɗorewa, mara zamewa, juriya kuma mai sauƙin gogewa.Yana tabbatar da amincin tsarin gwaji.
Tsarin ciki
1— — Wurin tuƙi
2——Yankin Aiki
3——Naúrar kula da cibiyar
4——Aikin siginar kuskure
5——Cibiyar kayan aikin gwajin abin hawa
6—— Na'urar gwajin ƙarfin ƙarfin lantarki
7——Sashin kariya
8——Generator
9—— Babban Gwajin Wutar Lantarki na USB
10——Red ɗin igiyar ƙasa
11—— bangon keɓewa
Duk tsarin ya haɗa da
Abu | Suna | Model No. | Qty |
1 | Vwata | ------------ | 1 |
2 | Multi-pulse na USB kuskuren gwajin gwaji | Saukewa: GD-4133 | 1 |
3 | Pulse coupler
| GD-4133S
| 1 |
4 | Cmai iya gano kuskure
| Saukewa: GD-4132
| 1 |
5 | High ƙarfin lantarki turu janareta | GD-2131H
| 1 |
6 | Cmai iya ganowa | Saukewa: GD-2134D
| 1 |
7 | Ciya huda na'urar | Saukewa: GD-2135 | 1 |
Saukewa: GD-2131H
Ana amfani da shi don haifar da motsin HV lokacin amfani da hanyar walƙiya mai ƙarfi don gano kuskuren impedance.
●Ƙarfin ƙonawa mai ƙarfi, max.Ƙarfin ƙonawa shine 1000W, za'a iya ƙone wurin raguwa a cikin ɗan gajeren lokaci kuma an rage juriya na raguwa.
●Idan aiki tare da GD-4133 Cable Fault Tester, akwai hanyoyi guda biyu:
a.Ƙananan bugun jini: Idan kawai ta amfani da GD-4133, buɗe kewayawa da ƙananan kurakuran ƙasa na kebul za a iya gano su, kuma ana iya auna tsayin kebul, ko ana iya gano saurin igiyar igiyar kebul.
b.Babban walƙiya mai walƙiya: Ana yin samfur ɗin nau'in nau'in ƙarfin ƙarfin bugun bugun bugun jini na kuskure ta hanyar fitar da tazara, wanda zai iya gano tazarar kuskure.
●Ƙirƙirar motsawar ƙayyadaddun mitoci.Idan aiki tare da GD-4132 Cable Fault Locator, akwai ayyuka masu zuwa:
a.Mitar sauti: gano wuri mai tsayi, Laifin walƙiya.
b.Don nuna hanyar kebul, gano kebul na musamman.
c.Don rushewar ƙarfe (mataccen ƙasa), ta amfani da ma'aunin maganadisu don gano daidai.
●Hakanan ana iya amfani dashi a gwajin jurewar DC HV.
●Mai shigar da wutar lantarki: AC 220V,50Hz
●Wutar lantarki mai fitarwa: DC 0-32kV (daidaitacce)
●rated ikon: 2kVA
●Max.makamashi: 2048J, 4uF
●Wutar lantarki ta DC: 32kV
●DC flashover halin yanzu: 63mA
●Max.karfin halin yanzu: 500mA
●Hanyar fitarwa: DC HV, lokaci ɗaya, sake zagayowar
●Lokacin fitar da zagayowar: 3-6 seconds
●Yanayin muhalli: 0-40 ℃
●Humidity: <75% RH
●Tsayi: <1000m
●Insulation matakin: A
●Girma: 430*540*410mm
●Nauyi: kimanin 31kg.
GD-4132 Mai gano Laifin Cable
Ciki har da babban naúrar, acoustic da firikwensin maganadisu, belun kunne na hana amo da caja.Ya dace don gwada kowane nau'in kebul na wutar lantarki tare da madugu na ƙarfe.Babban aikinsa shine gano madaidaicin wurin rufewa, gano kewaye da zurfin kebul na wutar lantarki.
●Acoustic Magnetic karba a lokaci guda
●Ƙarfin ƙarfin hana tsangwama
●Tare da belun kunne na hana surutu.
●320*240 LCD nuniGina babban ƙarfin Li-batir, tare da caja mai sauri.
●Nunin siginar sauti da Magnetic nuni, sigina da amo yana da sauƙin rarrabewa.
●Yin amfani da siginan kwamfuta don auna jinkirin sauti da maganadisu, ƙayyade maƙasudin kuskure daidai.Dangane da polarity na farko na magnetic waveform, yana iya gano wuri da gano hanya.
1. Aikin gano wuri
a.Ƙungiyar watsa siginar Acoustic: mitar cibiyar 400Hz, bandwidth 200Hz
b.Siginar riba: 80dB
c.Daidaitaccen wuri: 0.1m
2. Samar da Wutar Lantarki a.Gina-batir Li-batir, ƙarancin ƙarfin lantarki 7.4V, ƙarfin 3000mAH.b.Amfani da wutar lantarki: 300mA, ci gaba da aiki lokaci 9hours.c.Caja: shigar AC220V± 10%, 50Hz.Fitowar ƙima ta 8.4V, DC 1A d.Lokacin caji: 4 hours
3. Girma: 270mm*150mm*210mm
4. Nauyi: 1.5kg.
5. Yi amfani da yanayin zafi -10 ℃ - 40 ℃, zafi 5-90% RH, tsawo <4500m
GD-4133 Mai gano Laifin Cable
Ana amfani da GD-4133 Cable Fault Detectot don auna nisa tsakanin kurakuran na USB.Yana da sauƙi a yi aiki kuma tare da haɗin gwiwar abokantaka.
Ana iya amfani da shi kaɗai a ƙarƙashin yanayin bugun jini mara ƙarfi.A karkashin yanayin bugun jini halin yanzu, yana buƙatar yin aiki tare da janareta na babban ƙarfin lantarki na GD-2131.A ƙarƙashin yanayin bugun jini da yawa, GD-4133S ma'amala ya kamata a yi aiki tare.Bayan gano wuri mai nisa, GD-4132 ya kamata a yi amfani da mai gano kuskure don nuna kuskure.Ana iya haɗa waɗannan samfuran zuwa saitin babban aiki da ingantaccen tsarin gwajin kuskuren kebul.
●7inch LCD allo, sada zumunci dubawa.
●Hanyar gano nesa da yawa:
Hanyar bugun jini mara ƙarfi: ya dace da gano ƙarancin juriya, ƙarancin kewayawa, kuskuren kewayawa.Hakanan za'a iya amfani dashi a ma'aunin tsayin kebul, tsaka-tsakin haɗin gwiwa, haɗin T, da haɗin ƙare na USB.Hakanan ana iya amfani da wannan hanyar don gyara saurin igiyoyin ruwa.
Hanyar halin yanzu pulse: Ya dace da auna nisa na babban juriya, kuskuren lalacewa.Yin amfani da na'ura mai haɗawa na yanzu don tattara sigina daga waya ta duniya, yana sa mai amfani yayi nisa da babban ƙarfin lantarki.Wannan hanyar tana da aminci kuma abin dogaro.
Yawan bugun jini: hanyar ci gaba don auna nisa.Tsarin igiyar ruwa yana da sauƙin ganewa kuma daidaito yana da girma.
●Samfurin 200MHz na ainihi.Max.0.4m ƙuduri ƙuduri.Yana da ƙananan mataccen yanki kuma na musamman don gajeriyar kebul ɗin kuma kusa da kebul na kuskure.
●Taba allo kuma danna aikin maɓalli
●Kwafin PIP (hoton ajiya na wucin gadi)
●Za a sami babban taga kuma tagogin ajiya na wucin gadi uku za su iya duba nau'ikan igiyoyi uku tare.
●Ginin tsarin aiki
Gudanar da software na musamman don haɓaka software, wariyar ajiya da mayarwa.
●Ayyukan sikelin
Wurin farawa, lambobi 10, laifin kebul ɗaya da cikakken tsayi ɗaya na iya zama saiti.
Nuna ma'auni da tsarin gwaji tare
●Waveform ajiya da sadarwa tare da kwamfuta.
Ciki ajiya na waveforms.
Tare da USB, don saukewa ko loda bayanai
Sadarwa tare da kwamfuta
●Gudanar da wutar lantarki
Hasken baya yana rauni idan babu aiki a cikin mintuna 2 kuma a kashe wuta cikin mintuna 10 idan babu aiki.
Batir Lithium-ion Polymer da aka gina a ciki.
Lokacin aiki shine har zuwa awanni 5 don kowane amfani.
Harka mai ƙarfi, mai sauƙin ɗauka.
Hanyoyin ganowa | Hanyar ƙwanƙwasa ƙarancin wutar lantarki Ƙaddamar da hanyar halin yanzu Hanyar ƙwanƙwasa da yawa idan ta dace da GD-4133S |
Max.Mitar samfur | 200 MHz |
Riba iyaka | 0-70dB |
Ƙarƙashin ƙarfin wutar lantarki mai ƙarfi | 30V |
Max.ƙuduri | 0.4m ku |
Max.Gano kewayon | 100km |
Yankin matattu | 2m |
Baturi | Nickel-metal hydride baturi mai caji, lokacin juriya sama da 5 hours |
Sadarwar sadarwa | USB |
Tushen wutan lantarki | Shigar da AC220V, 50Hz, 2A na yanzu, cajin sa'o'i 8 |
Dim. | 274×218×81mm |
Nauyi | 3.5kg |
Yanayin Aiki | -10℃-40℃ |
Danshi | 5-90% RH |
Girma | <4500m |
GD-4133S Multiple Pulse Coupler
Yana aiki tare da GD-4133 Cable Fault Detector, wanda aka yi amfani da shi don gano kuskuren yatsa mai ƙarfi, kuskuren walƙiya, ƙarancin impedance ƙasa da kuskuren kewayawa na igiyoyin wutar lantarki.GD-4133S ya ba da siginar haɗaɗɗen bugun jini don GD-4133 kuma ya ware shi daga kayan aikin wutar lantarki.
●Amfani da mafi girman ci gaban fasaha na nau'ikan bugun jini da ma'aunin bugun jini. Canza fasalin igiyar ruwa ya fi sauƙin ganewa.
●Tare da kariya ta HV mai aminci, da'irar aunawa da babban ƙarfin ƙarfin kuzari an keɓe ta hanyar lantarki.
●Sauƙaƙe wayoyi, aminci kuma abin dogaro.
Ƙayyadaddun bayanai
●Wutar lantarki: 300V(PP)
●Izinin shigar da ƙarfin ƙarfin kuzari: <35kV
●Ƙarfin shigar da aka yarda da shi: <2000J
●Shigar da wutar lantarki: 220VAC, 50Hz
●Girma: 560*230*220mm
●Nauyi: 7kg.
GD-2134D Mai Gano Cable
GD-2134D Cable Identifier ya haɗa da mai watsawa da mai karɓa, ana iya amfani da shi don gano ganowa da zurfin igiyoyin igiyar ƙasa da bututun ƙarfe, kuma don gano kebul ɗin daga tarin igiyoyi.
●Nuna wurin bututu kai tsaye.
●Alamar Kibiya Hagu/ Dama don Binciken Hanyar Kebul.
●Ma'auni na ainihin bututun bututun yanzu da saƙon ƙarya/daidai a ƙarƙashin mitar ɗan lokaci.
●Maƙasudin daidai/ƙarya.Zai nuna gaba lokacin da aka gano kebul ɗin da aka gano daidai.In ba haka ba, zai nuna zuwa baya kuma zai nuna "?".
●Aunawa ta atomatik na zurfin da halin yanzu.
●Gane na kebul: Gane manne da kuma gano stethoscope.Gane manne zai iya auna girman girman yanzu da shugabanci na kebul daidai kuma ya ba da ingantaccen sakamako.Ganewar Stethoscope hanya ce ta gargajiya lokacin da bai dace ba don amfani da gano manne.Yana da sauƙin wayoyi don gano Stethoscope.
●Yin amfani da tarkace (na'urar haɗi na zaɓi) don gano wurin da ba daidai ba na rufin ƙasa.Ba lallai ba ne don daidaitawa zuwa matsayi na sifili.Kibiya tana nuna alamar kuskure.
●Cikakken ƙididdigewa babban madaidaicin samfuri da sarrafawa, tare da kunkuntar band mai karɓa da tsangwama mai ƙarfi.Yana da cikakken murkushe mitar wutar lantarki da tsangwama masu jituwa daga igiyoyi masu gudana kusa.
●Ganewa mai aiki da gano m.
●Babban baturin lithium da aka gina a ciki.Kashewar wutar lantarki ta atomatik lokacin da ƙarancin wutar lantarki ko babu aiki na dogon lokaci.
Mai watsawa
●Fitowa (Yanayin Uku): Fitowar haɗin kai kai tsaye, Fitowar Haɗaɗɗen Maɗaukaki (don zaɓi), ƙaddamar da Radiation.
●Mitar (6 don zaɓi): 640Hz, 1280Hz, 10kHz, 33kHz, 83kHz, gami da 640Hz da 1280Hz mitar mai rikitarwa ce.Yana iya gane aikin daidai / Ƙarya nuni da kuma gano bututu tare da taimakon Mai karɓa.
●Fitowar siginar kuskure don gano laifin bututun ƙasa.
●Fitar wutar lantarki: Max.10W, 10 matakai daidaitacce.
●Wutar lantarki na fitarwa na haɗin kai tsaye: Max.150Vpp.
●Daidaita impedance ta atomatik da ayyuka na kiba&gajeren kariya.
●Ƙarfin wutar lantarki: Batirin Lithium mai caji na ciki, 4pcs, samfurin no.18650.7.4V, 6.8Ah.
●Mai ƙarfi kuma mai ɗaukuwa.
Mai karɓa
●Yanayin shigarwa: ginanniyar nada mai karɓa, karɓar manne(na zaɓi), echometer (na zaɓi), Rack(na zaɓi).
●Ƙungiyoyin mitar ganowa guda biyu: mitar wuta da mitar rediyo (RF).Babu buƙatar haɗi tare da janareta mitar odiyo.
●Karɓar mitar:
Mitar gano aiki: 640Hz, 1280Hz, 10kHz, 33kHz, 83kHz
Mitar gano m PF: 50/60Hz da 250/300Hz (mai daidaita mai amfani)
Mitar gano m RF: mitar cibiyar shine 10kHz, 33kHz, 83kHz bi da bi.
●Yanayin ganowa: Hanyar kololuwa, kunkuntar hanya, Hanyar banza.
●320*240 pixel nuni.
●Batir lithium mai cajin da aka gina a ciki, baturi 2pcs 18650 Li, mai ƙima.7.4V, 3.4Ah.
●Mai ƙarfi kuma mai ɗaukuwa.
Wasu ƙayyadaddun bayanai
●Girman: Transformer 270*220*85mm, Mai karɓa 700*270*120mm.
●Nauyi: mai watsawa 2.2kg, mai karɓa 2.2kg.
●Caja: shigar da AC 100-240V, 50/60Hz, fitarwa DC 8.4V, 2A.
●Yanayin aiki: Zazzabi -10--40 ℃.Humidity 5-90% RH, Tsayinsa <4500m.
GD-2135 Cable Puncture Na'urar
GD-2135B Cable Puncture Device shima mai gano kebul, don gano kebul daga tarin igiyoyi.
Na'urar huda mara lafiya ce wacce ba ta tuntuɓar juna ba, tare da sarrafa nesa da lokaci.
Wannan na'urar ta ƙunshi sassa biyu, na'urar ƙusa da na'urar sarrafawa.Yana da ƙarfin baturi, wanda ke ware na'urar huda daga tsarin wutar lantarki, don tabbatar da amincin samar da wutar lantarki.
●Ya dace da huda kowane nau'in kebul na wutar lantarki, mai aminci kuma abin dogaro.
●Yanayin aiki guda biyu, gami da nesa da lokaci.Maɓallai biyu da za a yi amfani da su don shigar da yanayin aiki, tabbatar da amincin mai aiki.
●Maɓallai biyu masu nisa (maɓallin C da D suna danna lokaci guda).Don tabbatar da ingantaccen karɓa, eriya mai watsawa na kula da nesa ya kamata a cire gaba ɗaya.
●Amfani da bindigogi biyu don huda ta kusurwoyi biyu.Ayyukan gwaji guda ɗaya don gama huda biyu.
●Tare da ƙararrawar sauti da nuni LCD.
●Ƙirar kariya da yawa ta injiniyoyi da na'urorin lantarki.
●An ƙirƙira ta musamman don huɗa na USB, gyarawa kai tsaye akan kebul ɗin, shigar a kowane kusurwa.
●Yin amfani da ƙarfin baturi, dace da amfanin daji ba tare da samar da wutar lantarki ba.Hakanan, yana keɓance na'urar huda daga tsarin wutar lantarki, don tabbatar da aminci.
●Nisa nesa mara waya: ≤ 20M.
●Cable aikace-aikace: duk ikon igiyoyi ≤ ¢125mm
●Ikon aiki: 6pcs 1.5V baturi.
●Yanayin aiki: zazzabi -10--50 ℃, zafiRH <95%.
●Weight: 15kg ciki har da aluminum case.
●Girma: 48*45*16cm