GDUD-PTM Ultrasonic Flaw Detector For Electrical Power Tower
●TFT allon launi na gaskiya.
●Yin amfani da manyan fasahar tsarin dijital da aka haɗa, alamun aikin lantarki na kayan aikin an ƙirƙira su da ƙera su bisa ma'aunin EN 12668.1-2000.
●Batir lithium polymer mai girma da aminci da fasahar sarrafa wutar lantarki, ƙararrawa ta atomatik da kariya.Za a iya saita na'urar ajiyar allo ta atomatik don sanya kayan aiki su kasance masu ƙarfi da ƙarfi da tsayi, kuma don tabbatar da ci gaba da gano aibi.
●Software na aikace-aikacen da ke haɗa ayyukan sarrafawa masu hankali da ƙarfi, ƙirar mai amfani da karanta kai tsaye da yanayin aiki, ko yanayin aiki na maɓalli ɗaya na dijital.
●Tashar saiti mai girman ƙarfin gano sigogi, dacewa ga masu amfani don aiki akan abubuwan gano daban-daban.Ƙaƙƙarfan ma'ajiya na bayanai da ƙarfin bincike na tsaye, haɗe tare da kwanan gano aibi na ainihin lokaci da saƙon agogon aiki tare da rikodi, suna sa ganowa cikin sauƙi.
●Tare da m nisa square kalaman bugun jini janareta, da m ƙarfin lantarki watsa don samun m watsa ikon.Saitunan damping masu dumbin yawa suna ba da damar bincike don dacewa da dacewa da kayan aiki.
●Kyakkyawan halayen amplifier da halayen bandeji.Amplifier yana da daidaito na 0.1dB, tare da fadi-band da kunkuntar hanyoyin aiki, kuma ana iya auna mitar bincike a ainihin lokacin, wanda ke ba da mafi kyawun sakamakon ganowa lokacin da mai amfani ya gano kayan daban-daban.
●Tare da kewayon ganowa mai faɗi (har zuwa mita 6) da ƙudurin sigina mai ƙarfi, min.0.1mm m daidaitacce kewayon.Zaɓi kewayon da ya dace da bincike mai dacewa don kyakkyawan ƙudurin filin kusa.
●Kyakkyawan kayan aiki mai sauri-sauri na ainihi aiki da ingantaccen ƙira na aikin sarrafa mitar bugun jini don saduwa da mafi kyawun sakamako don nau'in kristal daban-daban da nisan ganowa.Nunin echo yana da tasiri mai ƙarfi kuma ba shi da ƙura.
●Canje-canje ta atomatik don bincike da farfajiyar lanƙwasa, wanda ke haɓaka haɗawa tsakanin binciken da abin gwaji kuma yana tabbatar da daidaito.
●Tare da aikin lanƙwan nisa-amplitude (DAC), sauti mai sarrafa shirye-shirye da sarrafa ƙararrawa haske.
●Tare da kebul na USB mai sauri, sauƙin sadarwa tare da kwamfutar, tallafawa ayyukan sarrafa kwamfuta da shirye-shiryen kan layi.
●Hasken aluminum gami da hannu wanda ke riƙe da gidaje, wanda ke da kyakkyawan aikin hana tsangwama.Haɗu da aji kariyar IP65.
Watsawa/karba
| Wutar lantarki mai watsawa | 600V |
| Mitar samfur | 100MHz (Max.) |
| Mitar maimaita bugun jini | 60Hz |
| Daidaitawar impedance | 50Ω/500Ω |
| Yanayin aiki | Mai watsa kai da karɓa/ Mai watsawa ɗaya da karɓa ɗaya/ Shiga |
| Ƙaddamarwa | ≥36dB(5N14) |
| Matsakaicin ƙarar wutar lantarki | ≤ |
Ƙara/gane
| Tashin hankali | ≥60dB (zurfin 200mm, Φ2Flat kasa rami) |
| Riba | 0~110dB, mataki 0dB/0.1dB/1dB/2dB/6dB domin zabi |
| Daidaiton Amplifier | ± 1dB |
| Kuskuren layi na tsaye | ≤3% |
| Riba ta atomatik | 10% -90% |
| Rage Rage | ≥35dB |
Tushen lokaci
| Kewayon ganowa | 10-6000mm, 0.1,1 da 10mm mataki atomatik saitin |
| Kuskuren layi na kwance | ≤0.1) |
| Sautin sauti | 1000-16000m/s, mataki shine 1m/s |
| Sifili diyya (jinkirin bincike) | 0 - 500.0 |
| Nuni kwanon rufi | 0-1000.0mm;0.1, 1mm mataki atomatik saitin |
Lankwasa
| DAC lankwasa | Nisa-amplitude curve(DAC), 2~10pcs reference point |
| 4 ƙarin madaidaitan dB masu lanƙwasa |
Sarrafa sigina
| Danne sigina | 0-90%, madaidaiciya |
| Ƙofar ganowa (1 guda) | Matsayin farawa / faɗi / tsayi ci gaba da daidaitawa |
| Ƙararrawa mai kyau/mara kyau a cikin ƙofar | |
| Fitowa (sauti da ƙararrawar haske). | |
| Zaɓin ma'aunin sigina a cikin ƙofar | |
| Yanayin aunawa | Hanyar sauti/tazarar kwance/zurfin nunin lissafin ainihin lokacin |
| TOF (lokacin tashi) ma'aunin nunin lissafin lokacin gaske | |
| Nuni mai ƙarfi na karkatar da hanyar sauti | |
| Lissafin ma'aunin karatu a tsaye | |
| Ƙididdigar tunani da matsayi na zaɓi |
Aikin gano aibu
| Tashoshi | ƙungiyoyi 20 |
| Adana | 500 echo sakonni |
| Nunawa | Cikakkun daskare/ daskarewar magana |
| Lankwasa ambulaf | Nuni rikodin ambulan kololuwa |
| Agogon lokacin gaske | Bibiyar kwanan wata/lokaci, daidaitaccen lokacin agogo |
| Interface | USB tashar jiragen ruwa, goyon bayan kwamfuta sadarwa da kuma management |
Nunawa
| Nunawa | Babban haske, nunin TFT launi na gaskiya, inci 5.7 |
| Yawanci | NTSC (60Hz) |
Tsari da yanayin amfani
| Baturi | Baturin lithium polymer, lokacin aiki ≥ 10 hours |
| Girma da nauyi | 210mmx165mmx50mm,1.8kg (tare da baturi) |
| Yanayin yanayi | -5 ℃ - 60 ℃ |
| Dangi zafi | 20-90% RH |
| Babban Unit | guda 1 |
| Adaftar wutar lantarki | guda 1 |
| HF anti-EMI bincike na USB | 2 guda |
| Kebul na USB | guda 1 |
| Bincike | 2 guda |
| Module | guda 1 |
| CD | guda 1 |
| Jagorar mai amfani | 1 kwafi |
| Rahoton Gwajin Masana'antu | 1 kwafi |