-
GDUP-3000 Tsabtace Sine Wave AC Samar da Wuta
GDUP-3000 shine madaidaicin šaukuwa šaukuwa tsantsa igiyar igiyar ruwa akan wurin gwajin wutar lantarki na AC.Har ila yau, an san shi da tashar wutar lantarki ta AC da DC, wutar lantarki ta gaggawa ta AC da DC, wutar lantarki ta gwaji, wutar lantarki ta wayar hannu.
-
GDUP-1000 Mai Sauƙi Mai Sauƙi Mai Sauƙi Mai Tsabtace Sine Wave akan Wurin Samar da Gwajin AC
GDUP-1000 shine madaidaicin šaukuwa šaukuwa tsantsa igiyar igiyar ruwa akan wurin gwajin wutar lantarki na AC.Har ila yau, an san shi da tashar wutar lantarki ta AC da DC, wutar lantarki ta gaggawa ta AC da DC, wutar lantarki ta gwaji, wutar lantarki ta wayar hannu.
-
GDC-9560B Tsarin Wutar Lantarki Mai Nazari Chromatograph Mai Nazari
GDC-9560B Gas Chromatograph Analyzer shine yin nazarin abun cikin iskar gas na mai mai rufi ta hanyar iskar gas.Yana da tasiri don yin hukunci idan kayan aikin yana da kuskure kamar zafi mai zafi, fitarwa ko a'a, don tabbatar da amincin grid ɗin wutar lantarki.
-
GDOH-II Mai Gwajin Abun Gas Mai Insulating
GDOH-II Insulating Oil Gas Gwajin Abun Gas sabon ƙarni ne mai gwadawa da ke ɗaukar babban firikwensin inganci da aka shigo da shi da sabuwar fasahar firikwensin.Ya dogara ne akan ma'aunin masana'antar wutar lantarki na DL423-91 da ma'auni na ƙasa masu dacewa.
-
GDW-102 Mai gwada Dew Point Mai (Coulometric Karl Fischer Titrator)
Ana amfani da fasahar Coulometric Karl Fischer don auna ma'auni daidai danshi samfurin da aka auna ya ƙunshi. Ana amfani da fasaha sosai don daidaito da farashi mai arha. Model GDW-102 yana auna daidai danshi akan samfurin ruwa, m da gas bisa ga fasaha.
-
GDBS-305 Mai gwada Kofin Rufe Wulashin atomatik
GDBS-305 na atomatik rufaffiyar kofin filasha ma'auni shine na'urar gwajin rufaffiyar ma'aunin filasha don samfuran man fetur.Yana amfani da ƙirar ƙirar ƙira wacce runduna ɗaya zata iya sarrafa tanderun gwaji da yawa, don gwada samfurori daban-daban a lokaci guda ko daban.
-
GDZD-601 Atomatik Multi-Ayyukan Insulation Mai Shaker
Multi-Aiki Shaker Ana amfani da a dakin gwaje-gwaje don gwada zafi, girgiza, degas iri daban-daban na ruwa karkashin m zazzabi da wani ƙayyadadden lokaci.Ana sarrafa shi ta micro-kwamfuta don gane hulɗar mutum da injin.
-
Saitin Gwajin Babban Wuta na AC don GIS
AC Resonant Test System for Substation Electrical Equipment, yafi hada da m mitar samar da wutar lantarki, Excitation Transformers, Reactors, Capacitive dividers, wanda aka tsara don AC jure ƙarfin lantarki gwajin na substation lantarki kayan aiki a 500kV ko kasa.
-
PD Tsarin Gwajin Mita Mai Canjin Kyauta
GDYT-350kVA / 70kV PD Tsarin Gwajin Resonant kyauta ya ƙunshi PD mai sauƙin mitar wutar lantarki kyauta, akwatin auna HV, mai canzawa mai motsawa, mai warewa mai canzawa, Resonant reactor, da mai rarraba wutar lantarki.
-
Saitin Gwajin Hipot Tare da Kulawa ta atomatik
Gwajin AC hi-pot hanya ce mai inganci kuma kai tsaye don gwada ƙarfin rufi don kayan lantarki, na'urori ko injuna.Yana bincika lahani masu haɗari waɗanda ke tabbatar da ci gaba da aiki na kayan lantarki.
-
Gwajin Ƙarfin Batir GDBT-8612
A matsayin maɓalli na tsarin wutar lantarki, dole ne a gwada batura kuma a kiyaye shi kowace shekara, kwata ko ma kowane wata kuma ana buƙatar bincika bayanan gwajin su akai-akai.
-
GDZRS-20A Mai Gwajin Juriya na Mataki Uku na DC
Wannan gwajin saurin juriya na DC (wanda ake kira da DC winding resistance tester) shine sabon samfuri na zamani don auna juriyar DC na masu taswira.An inganta shi don auna juriya na DC na iska mai hawa uku na manyan injina.Ana iya gwada juriyar DC na iska mai hawa uku na taswira lokaci guda.Don wutar lantarki mai sarrafa wutar lantarki, ba lallai ba ne a sauke mai canza famfo kai tsaye, kuma lokacin aunawa shine kashi ɗaya bisa uku na ma'aunin al'ada guda ɗaya, wanda zai iya rage yawan lokacin aiki da ƙarfin aiki.Mitar juriya kai tsaye tana ɗaukar babban allo mai nunin kristal na ruwa, duk ƙirar sinawa mai hoto, bayyananne da fahimta, kuma aikin yana da sauƙi.Kuma sanye take da firintar panel da ƙwaƙwalwar ajiya mai ƙarfi mara ƙarfi, zaka iya adanawa da buga sakamakon auna cikin sauƙi.Bayanan gwajin sun tsaya tsayin daka, da sauri kuma ana iya maimaita su, kuma shine mafi kyawun zabi don auna juriya na DC na masu canji a wurin.











